hyster

Lift button is pressed

  • Cause of failure:

    1. Lifting contactor cables are wrongly connected (Right connection: red cable + down, yellow cable - up)

    2. Lifting contactor short circuit.

    3. Lifting contactor faulty (coil short circuit)

    Tools: multimeter; socket wrench (#8); open-end wrench(#10; #14)


    Required information for warranty claims:

    1. Photo of truck name plate;

    2. Photo of error code ( displayed on handle screen);

    3. Video of lifting contactor resistance measurement;

    4. Photo of the claimed part.


Step1: Check lifting contactor

Check lifting contactor

Step2: Replace lifting contactor

Replace lifting contactor

Copyright © 2022 staxx Co., Ltd. All rights reserved.