hyster

Truck lifting without load, not lifting with heavy load

  • Cause of failure: wrong operating or overflow valve failure

    Checking method:

    1. Make sure weight of the load is centered and no overloading

    2. Adjust the tightness of relief valve

    3. Check if the base of relief valve steel ball is loose


Step 1: Operating instructions for adjusting overflow valve

Adjust overflow valve

Step 2: Operation instructions for adjusting loose overflow valve steel ball base

Adjust overflow valve steel ball base

Step 3: Check and replace the heart-shaped seals of gear pump

Replace the heart-shaped seals of gear pump